Page 384 - Catalogue-UK-ED25
P. 384

BATHROOM / POOL ZONES





                                                                              WHAT IP RATING DO I NEED?

                                                                              Zone 0  ≥IPX7
                                                                              Only 12V AC rms or 30V ripple-free DC SELV,
                                                                              transformers must be sited outside Zones 0,1,2.
                                                                              Zone 1  ≥IPX4
                                                                              Where water jets are likely to be used for cleaning
                                                                              purposes in communal baths & showers at least
                                                                              IPX5 is required.
                                                                              Zone 2  ≥IPX4
                                                                              Where water jets are likely to be used for cleaning
                                                                              purposes in communal baths & showers at least
                                                                              IPX5 is required.
                                                                              Outside zones 0, 1 & 2
                                                                              No specific IP rating. Where water jets are
                                                                              likely to be used for cleaning purposes in communal
                                                                              baths & showers at least IPX5 is required.





































                     is the interior of the pool, bath tub or shower basin.
                     For showers without a basin, the height of zone 0 is
                     10cm and its surface extent has the same horizontal
                     extent as zone 1.



                     Zone 1                                             Zone 2
                     is the three-dimensional space limited by the      is the three-dimensional space limited by the
                     finished floor level and the horizontal plane      finished floor level and the horizontal plane
                     corresponding to the highest fixed shower head     corresponding to the highest fixed shower head
                     or water outlet or the horizontal plane lying 2.25m   or water outlet or the horizontal plane lying 2.25m
                     above the finished floor level, whichever is higher   above the finished floor level, whichever is higher
                     and the vertical plane circumscribing the bath tub   than the vertical surface at the boundary of zone
                     or shower.                                         1 and the parallel vertical surface at a distance of
                                                                        60cm from the zone 1 border.
                     For showers without a basin, the limiting vertical
                     plane of zone 1 is at a distance of 1.2m from the   For showers without a basin, there is no zone 2 but
                     centre point of the fixed water outlet on the wall or   and increased zone 1 is provided by the horizontal
                     ceiling.                                           dimension of  1.2m.


       382